Brugg Contec

EMPA long-term Load Test for Synthetic Reinforcement Fibers

The durability of synthetic fibers in aggressive environments is often questioned. A long-term test undertaken by the Swiss material tes­ting and research institute (EMPA) as part of a KTI project (KTI 10652.1 PFIW-IW) has been able to disprove this assumption for the two-component high-performance fibers from the Swiss manufacturer Brugg Contec.

Test Arrangement

The tests were carried out with two different types of concrete (shotcrete mix and in-situ concrete mix). Different quantities of the Concrix fibers (0.5 % vol. = 4.55 kg/m3 and 1 % vol. = 9 kg/m3) were added to each type of concrete and also for comparison conventional steel fibers with a dosage of 50 kg/m3 concrete. Five square panels (600 x 600 x 100 mm) were made from each mix according to SIA 162/6 (1999) or EN 14488-5 (2006). The flow table consistency, air content and density were determined according to the applicable European standards.

After the specified hardening time of 28 days, the panels were broken, then loaded until a defined crack width and unloaded. Then the various test panels were exposed at regular intervals to various solutions, specifically salt solution, sulphate solution and two percent sulphuric acid, for the duration of one year. Additionally one panel was exposed to outside weather and one further was stored in a climate chamber at 20 oC/90 % RH as reference. After one year, the panels were once again fixed in a test rig and loaded in order to check their residual strength.

Summary of the Results

The panels reinforced with steel fibers showed, as expected, clear signs of corrosion. The result of renewed loading showed correspondingly clearly a reduction of the residual strengths of the fibers. With the Concrix-reinforced panels, on the other hand, the load could even be increased again after reloading, which clearly demonstrates that these synthetic fibers can successfully resist the effect of aggressive solutions.

The currently used square panel test shows the load-bearing capacity of the test panels as a snap-shot in time, after the specified
28 days hardening time of the concrete. The long-term effects of the environmental influences on the reinforcement is not considered.

But precisely this long-term effect is of interest, since structures such as tunnels should have the longest possible lifetime with the lowest possible maintenance costs. Tests at respected institutes with the test arrangement described here clearly show the strengths and weaknesses of the various reinforcement solutions.

x

Related articles:

Issue 06/2016 Reinforcement

Refurbishment with Fibre Concrete

In the course of the refurbishment of the Swiss Zuben Tunnel on the Grimsel Pass road near Innertkirchen, the existing chloride-damaged concrete lining of the road tunnel, which was built in the...

more
Issue 08/2012 Costa Rica

Bicomponent Synthetic Macro Fibres for Power Plant Tunnel

For years if not for decades steel fibre reinforced shotcrete has been applied in tunnelling with success. The various problems associated with steel fibres such as e.g. complicated handling owing to...

more
Issue 04/2023

High Performance Steel Fibres Offer New Possibilities for Permanent Sprayed Concrete Lining

Conventionally, tunnels constructed using sprayed concrete have been based on a temporary sprayed concrete lining to stabilize the opening after excavation and to contain short to medium-term loads....

more
Switzerland

Swiss Tunnelling Society: 50th Anniversary With Switzerland-Wide “Insight Into the Underground”

50th Anniversary of the Swiss Tunnelling Society In 2023, the Swiss Tunnelling Society of the SIA (Swiss Society of Engineers and Architects) celebrates its 50th anniversary. The Swiss Underground...

more
Issue 01/2023 Switzerland

Swiss Tunnelling Society: 50th Anniversary With Switzerland-Wide “Insight Into the Underground”

“Switzerland has a tradition of over 150 years in underground construction. Unique structures for transport, hydropower, research and the military bear witness to this. As an established group of...

more